Skip to calculator

Floor Joist Calculator

A 13 ft span in Douglas fir-larch #2 needs 2×10 joists at 16 in. on center, allowed 15 ft 7 in.: 13 joists, 14 ft long, for a 16 ft floor. A 2×8 at 16 in. stops at 12 ft 9 in.. Enter your span below.

Floor joist calculator

Span is the clear distance between the walls or beams the joists sit on. Floor length is the distance the joists are spaced along. The grade is stamped on each board; #2 is what most yards stock.

Loads, finish and prices (optional)

Dead load is the weight of the floor itself and anything fixed under it. The code tables give 10 and 20 psf; Sacramento’s handout uses 10 for joists with no ceiling below and 20 with a finished ceiling. A mortar-bed stone floor can weigh more than 20 psf by itself, which these tables don’t cover.

Enter the joist span and floor length.

Southern Pine Spans Less Than Many Calculators Say

Look up how far a 2×10 southern pine #2 joist spans at 16 in. on center and you will find answers from about 15½ ft to over 17 ft on popular calculator and code-explainer sites. The 2021 IRC table allows 14 ft for a living area. So do the Southern Forest Products Association’s own span tables, and so does a lumber yard’s published chart.

The gap is not rounding. The design values for visually graded southern pine were lowered for every size and grade from June 1, 2013, after a large round of full-size testing, and the span tables were redone with them. Southern pine #2 now spans less than Douglas fir-larch #2 in every size; the same 2×10 in Douglas fir is allowed 15 ft 7 in.. On a 13 ft span, that is the difference between using 93% of the allowed span and 83%. This page uses the 2021 IRC Tables R502.3.1(1) and R502.3.1(2) for all four species, and we check them against published city handouts and the SFPA tables cell by cell.

Pick by Span, Then by Lumber

The code table gives one span for each species, grade, joist size, spacing and dead load. Most calculators make you guess a size and check it. This one does it the other way round: enter your span and it tests all sixteen size and spacing combinations at once.

Take a 13 ft span on a 16 ft floor in Douglas fir #2. A 2×8 only works at 12 in. A 2×10 works at 12, 16 and 19.2 in., and a 2×12 at every spacing. The headline picks the smallest joist at 16 in., here a 2×10 with 13 joists of 14 ft, because that is the most common layout. The box beside it shows the option that uses the least lumber: 2×10 at 19.2 in., 11 joists and about 310 board feet against 357 for the 16 in. layout, rims included. Wider spacing saves wood, but check that your subfloor panel’s stamped span rating covers it. Type your yard’s prices and the options re-rank by cost instead.

Bedrooms Are Allowed Longer Spans

The IRC has two floor tables. Bedrooms, and attics reached by a fixed stair, are designed for a 30 psf live load; every other room uses 40 psf. That changes the answer: a Douglas fir #2 2×8 at 16 in. is allowed 14 ft 2 in. under a bedroom and 12 ft 9 in. under a living room. Most span calculators only show the living-area figure. Use the bedroom table only for rooms that will stay bedrooms; a room framed at the bedroom limit is short if it later becomes a home gym or a library.

The Code Span Is Not a Stiff Floor

Both tables limit sag under the full live load to the span divided by 360. On a 13 ft span that is 156 ÷ 360, about 0.43 in., which passes code but can feel springy when someone walks across the room. The result shows how much of the allowed span you are using; past 90% it suggests going a size up or closer together.

Tile adds its own rule. The Tile Council of North America limits ceramic and porcelain floors to the same L/360, so the code table already covers them. Natural stone is stricter: the Natural Stone Institute and TCNA call for L/720 under the full load, dead load included. The code has no stone table, so the calculator works one out from the same lumber stiffness the tables use and labels it rough. For the 13 ft floor, a 2×10 at 16 in. drops to about 12 ft and the pick moves up to a 2×12, good for about 14 ft 8 in..

Holes, Notches and the Ends

The span only holds if the joist stays whole. The IRC limits notches to one-sixth of the depth, not in the middle third of the span; that is about 1½ in. in a 2×10, which is 9¼ in. deep. End notches can go to one-quarter of the depth, and holes up to one-third, about 3 in., kept at least 2 in. from the top and bottom edges. Each end needs at least 1½ in. of bearing on wood or metal, or 3 in. on concrete or masonry, which is why the calculator adds 3 in. to the span before rounding up to a board length. A floor can cantilever past its support by no more than the joist’s depth unless it is built to the code’s cantilever tables.

What the Table Doesn’t Cover

The tables assume an even load spread over the floor. A cast-iron tub, a stone island, a post from the floor above or a gun safe is a point load, and needs a design check. Engineered I-joists and LVL span further but come with the maker’s own tables. Deck joists have a separate IRC table, and old joists that are notched, cracked or rotted can’t be judged from a span table at all. For any of those, the American Wood Council’s span calculator or an engineer is the next step.

Floor Joist Questions

In Douglas fir-larch #2 at 16 in. on center, 12 ft 9 in. under a living area and 14 ft 2 in. under a bedroom. At #2 and 16 in., spruce-pine-fir is allowed 12 ft 3 in. and southern pine 11 ft 10 in., all with a 10 psf dead load.

Douglas fir-larch #2 at 16 in. is allowed 18 ft 1 in. under a living area, and 20 ft 11 in. at 12 in. Southern pine #2 at 16 in. stops at 16 ft 6 in.. Boards over 20 ft are often special order, so a span near the limit can be limited by what the yard stocks.

The code allows it, but the span drops. A Douglas fir #2 2×10 is allowed 15 ft 7 in. at 16 in. and 12 ft 9 in. at 24 in. On a 16 ft floor, 24 in. needs 9 joists instead of 13; check the subfloor panel’s stamped span rating covers 24 in.

With the joists spanning the 12 ft way and spaced along the 16 ft wall at 16 in., you need 13 joists, 14 ft long, plus two 16 ft rim joists. In Douglas fir #2, a 2×8 is enough for a living area: it is allowed 12 ft 9 in..

For short spans. Douglas fir #2 2×6 is allowed 9 ft 9 in. at 16 in. and 10 ft 9 in. at 12 in. under the 40 psf living-area load. A shed that stores mowers, tools or bags of concrete can carry more than that, and the AWC publishes separate 60 psf span tables for heavier floors.

The code says joists under a wall running parallel to them must be sized to carry it, and doubled joists spread apart for pipes need solid blocking at no more than 4 ft on center. A bearing wall crossing the joists should sit within one joist depth of the support below (9¼ in. for a 2×10) unless the joists are sized for it.

Spans reproduce the 2021 IRC Tables R502.3.1(1) and R502.3.1(2). We build them from the lumber design values the way the AWC span tables do, and the build stops unless they match every published cell we hold: Sacramento’s 2022 handout, the SFPA southern pine tables, and the code text printed by Seattle and the ICC. The engine is tested on more than 60,000 combinations.

Written and checked by Kris Lynch. Not reviewed by a licensed professional. See our methodology. Spotted a problem? Tell us. Updates: Nov 2026, launched.

Related Calculators