Measure Where the Stair Lands, Not at the Deck
I replaced the steps on a deck I’d stained, three steps up from the backyard. Three steps sounds like the simplest stair there is, but it raises the same questions as a tall one: where the bottom step lands, how tall each riser is, and how much wood is left under the notches.
The first is the one most calculators skip. The rise that matters is from the top of the decking to the ground where the stair lands, and JLC, Fine Homebuilding and Trex all warn that this is not always straight down from the deck, because ground usually slopes away. The catch is that you don’t know where the stair lands until you know how many risers it has, and you don’t know that until you know the rise. Fine Homebuilding’s example deck measured 42 in., but 55 in. out the grade was 3 in. lower, for a real rise of 45 in.
Builders solve this by trial and error with a level and a tape. The calculator does the loop for you. Enter the height at the deck edge and how the ground falls, or the height you measured at a point further out, and it moves the landing out one tread at a time until the riser count stops changing. The default here is a 40 in. deck on ground falling 1 in. per foot: the stair lands 51 ¼ in. out, where the rise is really 44 ¼ in., which takes 6 risers of 7 ⅜ in. instead of 6⅔ in.
From Rise to Stair-Gauge Settings
Divide the rise by a target riser and round up to get the number of risers, then divide again for the exact height. The IRC allows up to 7¾ in. per riser and asks for at least 10 in. of tread, with every riser in a flight within ⅜ in. of the others. A deck stair usually starts one riser below the deck surface, so the deck is the top step and there is one fewer tread than risers. JLC’s worked example is a 102½ in. rise in 14 risers of 7.3214 in. with 11 in. treads, 143 in. of total run, marked every 13.2137 in. along the stringer. The calculator reproduces all four numbers.
Drop the Stringer
The stair gauges lay out every notch the same height, but the bottom step is different: every other tread sits on top of the stringer, adding its thickness, while the ground under the first step adds nothing. Fine Homebuilding and JLC both say to take one tread thickness off the bottom of the stringer, or the first step comes out taller than the rest by that much. With 2×6 treads that is 1½ in., four times the ⅜ in. the code allows between risers. The result prints the first riser as its own number. If the bottom lands on a pad or flooring that isn’t there yet, add its thickness back.
Throat Depth and 2×10 vs 2×12
Every notch removes wood, and what’s left under the notches carries the stair. The deck guide and JLC set the minimum at 5 in., measured to the saw kerf, and JLC finds overcut notches common in the stairs it inspects. The throat depends on the riser and run:
| Riser × run | 2×12 throat | 2×10 throat |
|---|---|---|
| 6 × 10 in. | 6.1 in. | 4.1 in. |
| 7 × 10 ¼ in. | 5.5 in. | 3.5 in. |
| 7 ½ × 10 ¼ in. | 5.2 in. | 3.2 in. |
| 7 ¾ × 10 in. | 5.1 in. | 3.1 in. |
A 2×12 passes across the normal range, though a steep 7¾ in. riser leaves only a little over 5 in. A 2×10 fails every time, which is why cut stringers are 2×12. Fine Homebuilding’s rule is simply not to overcut the notches: stop the saw at the line and finish the corner by hand.
Span, Spacing and Support
A cut stringer may span no more than 6 ft horizontally between supports in the deck guide; past that it needs a post or landing partway. Two solid stringers can go to 13 ft 3 in. on a stair 36 in. wide. JLC’s 102½ in. example runs 11 ft 11 in., so it needs one. Space cut stringers no more than 18 in. apart, which gives three under a 36 in. stair; NADRA recommends 12 in., and composite treads have their own spacing rules. At the bottom, the stringers need a solid surface at least 3½ in. thick and 8 in. across, and JLC notes that stairs often fail sideways, when fasteners pull out, so the top connection matters as much as the bottom.
The Board You Buy
The usual stringer-length formula is the diagonal of the total rise and run. The real stringer ends at the rim below the decking and has a seat cut at the bottom, so the calculator measures the cut shape along the board instead. For the default stair the cut stringer is 66 9/16 in. on the board against a 67 ¾ in. diagonal, and an 8 ft 2×12 covers it. Sight down each board and put the crown up, as Fine Homebuilding advises, and cut one stringer first, test it in place, then use it as the pattern for the rest.
Stair Stringer Questions
Riser and tread limits are from IRC R311.7.5; stringer span, spacing, throat, width and landing rules are from the American Wood Council’s deck guide (DCA 6) as printed in Wisconsin’s deck code appendix; layout practice is from JLC and Fine Homebuilding. We test the engine on the examples above and on more than a million combinations of rise, run, slope, tread thickness and riser target.
- JLC: better stair stringer layout (measure at the landing)
- JLC: stair stringer layout worked example (102½ in. rise)
- JLC: cutting basic stairs
- JLC: common deck stair defects (5 in. throat, lateral loads)
- JLC: common defects in deck stairs (seat-cut bearing)
- Fine Homebuilding: framing stairs to an out-of-level landing
- Fine Homebuilding: laying out basic stair stringers
- Trex: how to calculate and cut stair stringers
- Wisconsin SPS 325 appendix (DCA 6): stringer span and throat
- Wisconsin SPS 325 appendix (DCA 6): stair width, spacing, bearing, landings
- Simpson Strong-Tie: deck stair connections (NADRA 12 in. spacing)
- Viewrail: IRC 2021 R311.7.5 tread and riser limits
Written and checked by Kris Lynch. Not reviewed by a licensed professional. See our methodology. Planning a whole staircase with landings or turns? Use the stair calculator. Spotted a problem? Tell us. Updates: Nov 2026, launched.