Bathroom Exhaust Fan Calculator

A 5 × 8 ft bathroom needs a fan rated at least 50 CFM, and a 4 in smooth duct can carry it up to 99 ft with one elbow. Enter your bathroom below for your fan size, duct check and noise limit.

Bathroom exhaust fan calculator

A tub with a shower over it counts as one tub. Fixtures change the answer once the room is over 100 sq ft.

Your duct

Measure from the fan to the outside cap. Not sure? The defaults are 4 in smooth, 10 ft, 1 elbow.

Prices (optional)
Enter the bathroom’s length and width.

The Number on the Box Is a Lab Number

When I renovated the bathroom in the apartment I bought in 2022, the paint on the ceiling was peeling, and when it came off there was moisture under it. I had an electrician put in a new fan, and the peeling stopped. That is the whole job of a bathroom fan: get the shower steam out before it soaks into paint, plaster and grout. Whether it does depends less on the fan you pick than people expect.

A fan’s CFM rating is measured on a test rig, pushing against a set amount of resistance. Most makers list two figures, at 0.1 and 0.25 in. of static pressure, and the box usually shows the bigger one. Real installs are harder. Greenheck measured an ideal short, straight run at 0.15 in., while setups closer to what gets built ranged from 0.30 to 0.45 in. Fine Homebuilding gives the result plainly: a fan sold as 50 CFM may move about 25 once it is connected to ductwork. ENERGY STAR now requires a certified bath fan to keep at least 70% of its 0.1 in. airflow at 0.25 in., which is one reason to look for the label. Whatever you buy, compare fans on the 0.25 in. figure in the spec sheet.

Sizing Your Room: Three Cases

The Home Ventilating Institute’s rule is about eight air changes an hour, which works out to 1 CFM per square foot of floor at an 8 ft ceiling, with 50 CFM as the smallest fan for any bathroom. Three rooms show how it plays out.

A 5 × 8 ft hall bath is 40 sq ft. That is under HVI’s 50 sq ft line, so the answer is the 50 CFM minimum, which is also the code minimum for a fan on a switch. A 7 × 9 ft bathroom is 63 sq ft and needs 63 CFM, so you would buy a 70 or 80.

An 8 × 10 ft bathroom with a 10 ft ceiling holds 800 cu ft of air, a quarter more than the same floor at 8 ft. HVI only says taller rooms may need more, so the calculator goes back to the eight air changes the rule stands for: 800 × 8 ÷ 60 is 107 CFM, not the 80 the floor area alone suggests.

A 12 × 10 ft primary bath is 120 sq ft, and past 100 sq ft HVI switches to counting fixtures: 50 CFM each for a toilet, a shower and a tub, and 100 for a jetted tub. Toilet, shower and tub come to 150 CFM. If the toilet sits in its own closet with a door, HVI wants a fan in there too, so the plan becomes a 100 CFM fan over the shower and tub plus a 50 CFM fan in the closet. When a room like this also has a ceiling over 8 ft, the calculator uses the air-change figure if it comes out higher than the fixture count.

The Duct Decides What You Actually Get

Every bend, foot of pipe and ridge in a flexible duct adds resistance. The building code deals with this in a prescriptive table, the same one in ASHRAE standard 62.2, that says how long a duct of each size and type can run for a fan of a given rating at 0.25 in. It assumes no elbows, and you take 15 ft off the allowed length for each one.

The table is blunt about the most common install, 4 in flexible duct. For a 50 CFM fan it allows 56 ft. For an 80 CFM fan it allows 4 ft, so a single elbow rules it out. For 100 CFM and up, 4 in flex is not allowed at all. The same 80 CFM fan on 4 in smooth metal duct gets 31 ft, and a 5 in flex duct gets 81. That is the gap between the box and the room: a larger fan on the old 4 in flex hose often moves no more air than the small one it replaced, just more noisily.

The calculator reads your fan size into the right column, takes off your elbows, and tells you whether the run passes, and if not, the smallest duct that would. The code also lets a longer run pass if it meets the fan maker’s own duct chart, or if the airflow is measured once it is in, so a fail here means check, not stop.

How Quiet It Needs to Be

Noise is rated in sones, and lower is quieter. ENERGY STAR caps certified bath fans at 2.0 sones from 10 to 200 CFM and 3.0 above that. ASHRAE 62.2 asks for 3 sones or less on a fan you switch on and off, and 1 sone or less on one that runs all the time. A quiet fan matters more than it sounds, because people turn off a loud one early, and a fan that is switched off moves no air at all.

What It Costs

HomeGuide puts a straight replacement, using the old duct and wiring, at $150 to $550, and a new fan vented outside through a wall or roof at $250 to $950, with the fan itself $20 to $400 of that. Thumbtack’s national average is $183 to $444. The big swing is the vent: cutting, capping and sealing a new roof opening adds about $150 to $500 according to LatestCost, and new wiring where there was no fan means an electrician. Type your own quotes into the price fields to see the total.

Bathroom Fan Questions

Not by itself. HVI says airflow above its minimums is fine and costs little extra energy, so going up one size is reasonable. The limits are elsewhere: a 4 in duct is only allowed up to a 100 CFM fan, and ENERGY STAR lets fans over 200 CFM run at 3.0 sones instead of 2.0, so a big fan can mean a bigger duct and a louder room.

No. The fan has to be ducted to the outside, and the U.S. Department of Energy’s Building America guide adds that the cap should sit at least 10 ft from any mechanical air intake and 3 ft from a gravity intake such as a vent, citing IRC section M1504.3. Moist air dumped in an attic can condense on the cold roof deck.

Unless it has a window that opens, plan on one. The code minimum for a bathroom or toilet room is 50 CFM for a fan on a switch or 20 CFM for one that runs all the time. A 4 × 5 ft powder room is 20 sq ft, well under HVI’s 50 CFM floor, so the smallest common fan covers it.

About an hour, according to the Building America guide from Pacific Northwest National Laboratory, which also suggests a timer switch rather than a plain on/off switch, so a 60 minute timer is the simple fix. A humidity-sensing fan does the same job without anyone remembering.

Yes, with an inline fan mounted in the attic and a duct to each room; HomeAdvisor notes one inline fan can serve several bathrooms. Size it for the total, so a 50 CFM and an 80 CFM bathroom need 130 CFM, which the code’s duct table reads in the 150 column: 6 in smooth duct allows 112 ft there before elbows.

Often, and that is why HomeGuide puts a straight replacement at $150 to $550 against $250 to $950 for a new install. Check the size first. If the old duct is 3 in, the code table allows it only for a 50 CFM fan on 5 ft of smooth pipe, so a new 80 or 110 CFM fan on that duct will fall well short of its rating.

The sizing rules are HVI’s, the code minimums and duct table are from the International Residential Code and ASHRAE 62.2, the noise limits from ENERGY STAR and ASHRAE, and the costs from the price guides listed. We test the engine against every cell of the duct table, with up to 4 elbows and 7 lengths each, and on more than four hundred thousand room and fixture combinations.

Written and checked by Kris Lynch. Not reviewed by a licensed professional. See our methodology. Spotted a problem? Tell us. Updates: Nov 2026, launched.